> ## Documentation Index
> Fetch the complete documentation index at: https://docs.getrivet.ca/llms.txt
> Use this file to discover all available pages before exploring further.

# Body scan

> Phase 6 body-focused scan — catch residual disturbance after VOC reaches 7 and SUDS reaches 0.

The body scan is Shapiro's Phase 6 — the step after the positive
cognition is installed and before closure. The client holds the
original target memory and the installed positive cognition in mind,
then scans the body for any residual tension or disturbance. Anything
left over is processed with additional BLS until the scan is clear.

This template captures the scan and the residual-clearing work.

## What the template covers

A single screen with seven fields:

| Field                          | Type        | What it captures                                          |
| ------------------------------ | ----------- | --------------------------------------------------------- |
| **VOC at start of body scan**  | Slider 1–7  | Validity of the positive cognition entering the scan      |
| **SUDS at start of body scan** | Slider 0–10 | Subjective distress entering the scan                     |
| **Residual locations**         | Large text  | Where in the body the client noticed anything             |
| **Residual description**       | Text        | Quality (tightness, heaviness, ache, etc.)                |
| **BLS sets to clear**          | Integer     | Sets needed to clear the residual (0 if first-pass clear) |
| **Final clear**                | Boolean     | Body scan is clear on second pass                         |
| **Notes**                      | Large text  | Optional                                                  |

## When to use it

Phase 6 sits after a complete Phase 4 (desensitization to SUDS = 0) and
a complete Phase 5 (positive cognition installation to VOC ≥ 7). The
body scan is performed in the same session as those phases — it's the
final clinical step before Phase 7 closure.

The prerequisites are documentation-only in Rivet. The template doesn't
gate the scan behind a VOC or SUDS threshold; you apply the protocol
ordering yourself.

## Reading the scan

The clinical interpretation of the scan is:

* **Body scan clear on first pass** → target is fully processed. Move
  to Phase 7 closure.
* **Residual present** → additional BLS sets to clear; the body holds
  what cognition has cleared. Re-scan after each set.
* **VOC at scan \< 7** → Phase 5 is not complete. Return to Phase 5
  before scanning.
* **SUDS at scan > 0** → Phase 4 is not complete. Return to Phase 4
  before scanning.

The first two read like "is the target processed yet?" — the answer is
in the body, not just the cognition.

## How to launch it

In the EMDR Workspace or from the templates picker, search "body scan."
The template opens with the scan prompt at the top — read it to the
client to set up the scan, then fill the fields as you go.

The BLS that clears residual disturbance runs in the
[EMDR Workspace](/emdr/setting-up-an-emdr-session). Capture the
cumulative set count in the **BLS sets to clear** field.

## Field-by-field

### The scan prompt

A display-only instruction at the top of the template:

> Have the client hold the original target memory plus the installed
> positive cognition in mind, then scan the body for residual tension
> or disturbance.

Read it to the client to set up the scan.

### VOC at start of body scan

Slider 1–7. Validity-of-cognition rating entering the scan. Should be
≥ 7 if Phase 5 is complete. If it's lower, return to Phase 5.

### SUDS at start of body scan

Slider 0–10. Subjective-units-of-distress rating entering the scan.
Should be 0 if Phase 4 is complete. If it's higher, return to Phase 4.

### Residual locations

Large text field. Where in the body the client notices anything. Be
specific — "right shoulder," "low belly," "the back of the throat."
Specificity helps the next round of BLS focus.

### Residual description

The quality of the residual. Tightness, heaviness, ache, fluttering,
warmth, cold, pressure. The descriptor is part of the target for the
next BLS set.

### BLS sets to clear

Integer. Cumulative BLS sets used to clear the residual. **0** if the
first-pass scan was clear. Otherwise the count for however many sets
the clearing required.

### Final clear

Boolean. Body scan is clear on the second pass — no residual remains.
Check this when the clearing is done; leave unchecked if the session
ran out of time and the scan was incomplete.

### Notes

Optional large text field for anything that didn't fit the structured
record — pacing observations, dual-attention quality, anything that
informs the next session.

## What an incomplete body scan means

If the session ran out of time before the scan was clear, **don't
check the final-clear box**. Use the container or the calm place for
closure, and pick up the body scan at the start of the next session.
The unchecked box is the cue that there's still work to do on this
target.

## Citation

* **Shapiro, F.** (1995, 2001, 2018). *Eye Movement Desensitization and
  Reprocessing Therapy: Basic Principles, Protocols, and Procedures.*
  Guilford Press. Phase 6 body scan procedure documented in all
  editions of the canonical text.

The protocol is published clinical method. Rivet's field labels are
original.

## Related articles

<CardGroup cols={2}>
  <Card title="Future template" icon="forward" href="/clinical-templates/emdr/future-template">
    Phase 8 — the next phase after a clean body scan and successful
    closure.
  </Card>

  <Card title="The EMDR Workspace" icon="brain" href="/emdr/index">
    Where the residual-clearing BLS sets run.
  </Card>
</CardGroup>
