# Setting up an EMDR session

> A walkthrough of the Configure modal — rate, stimulus, modalities, sound, motion path, set count, backdrop, SUD check-ins, client phone haptics, per-client saved settings, and Flash technique (Beta).

When you tap **EMDR** in the call toolbar, the Configure modal opens on top
of your video session with a preview of the scene. Your client's screen
shows that scene while you're still choosing, and every change you make is
visible on their side as you make it — worth knowing before you scroll
through all sixteen backdrops in front of them.

<Tip>
  Rivet remembers your last configuration. The modal opens pre-populated
  with the settings you used last time — so a returning client who wants
  the same BLS as last week is one tap to **Start Set 1**.
</Tip>

## Per-client saved settings

When the session is tied to a client in your records, Rivet can remember
that specific client's settings separately from your general defaults. If
the client has saved settings, the modal shows a quiet caption — **"Using
this client's saved settings"** — and pre-fills the configuration from
them.

To save the current configuration as that client's defaults, check **Save
as this client's defaults** before you start or apply changes. Leave it
unchecked and saving works the way it always has — your practitioner-level
defaults, not tied to any one client. If the session isn't linked to a
client record, this option doesn't appear and nothing changes.

## Mode toggle — EMDR 2.0, Classic, and Flash

Top of the modal, mode pills. **EMDR 2.0** is the default. Tap **Classic**
or **Flash — Beta** to switch.

|                   | EMDR 2.0 (default) | Classic                    |
| ----------------- | ------------------ | -------------------------- |
| Rate              | 1.5 Hz             | 1.0 Hz                     |
| Modalities        | Visual + Audio     | Visual only                |
| Stimulus          | Butterfly          | Dot                        |
| Sound preset      | Soft drum          | Sine                       |
| Background        | Photo backdrop     | None (video shows through) |
| Dual-task prompts | On                 | Off                        |
| SUD check-ins     | Every set          | Baseline + end             |

Flipping the toggle resets every parameter to that mode's defaults. If
you've tweaked the rate or the sound and then flip modes, your tweaks are
replaced — by design, so the mode swap is clean. EMDR 2.0 is a research
protocol rather than an EMDRIA-adopted one; see
[The research behind EMDR](/emdr/the-research-behind-emdr) for where it
stands.

Flash mode is a different technique entirely — see the Flash technique
section below.

## Rate

The slider runs from **0.3 Hz to 2.0 Hz**. A "cap 2.0 Hz" label sits at the
right edge.

<Warning>
  The 2.0 Hz ceiling is a hard cap, not a UI suggestion. It holds wherever
  the speed can be set — this slider, the stepper during a running set, and
  any stored setting.
  See [Photosensitive epilepsy safety](/emdr/photosensitive-epilepsy-safety)
  for why.
</Warning>

Useful reference points:

* **0.3–0.7 Hz** — slow. Used in early Phase 2 testing or when a client
  reports visual overwhelm at higher rates.
* **1.0 Hz** — Shapiro Classic baseline.
* **1.5 Hz** — EMDR 2.0 default. Midpoint of the de Jongh / Matthijssen
  published 1.2–2.0 Hz range.
* **2.0 Hz** — upper edge of clinical norm and of safety.

## Stimulus shape

Five options:

* **Dot** — Shapiro Classic default. Maximum clinical familiarity.
* **Butterfly** — EMDR 2.0 default. The EMDRIA-adjacent silhouette
  recognizable to EMDR-trained therapists.
* **Flame** — a soft warm shape some clients prefer to a sharper geometric.
* **Star** — a five-point shape with more visual texture.
* **Square** — a clean geometric for clients who prefer neutral over
  symbolic.

All shapes render at the same pixel size and color regardless of the choice.
See [Visual bilateral stimulation](/emdr/visual-bilateral-stimulation) for
sizing and color.

## Modalities

Two pill toggles — **V** (visual) and **A** (audio). Tap to toggle either
on or off. One has to stay on; turning off the last one puts visual back.

* **V** is the moving stimulus. Turn it off for a client you've screened
  out of visual BLS and the set runs audio-only against a calm backdrop.
* **A** is the tone, which sits in whichever ear the stimulus is currently
  on rather than merely moving at the same rate. See
  [One movement, not three](/emdr/staying-in-sync).

EMDR 2.0 expects multimodal stimulation. Classic defaults to visual only.

## Client phone haptics

A row further down the modal turns on taps in your client's hand. Switch it
on and a card appears on your client's screen for them to scan with their
phone's camera — nothing to install on Android, a small Rivet companion on
iPhone. **Add a second phone** issues a second code, so one phone can sit in
each hand.

A paired phone doesn't run its own rhythm. It joins the one already
running, so the taps land on the turns of the stimulus. Two phones hold
opposite halves of the same rhythm without communicating with each other.

While a set is running, a **PHONE** marker joins the stats pill so you can
see at a glance whether a paired phone is still with you.

## Audio

A row of eight sound presets — **Sine**, **Triangle**, **Soft drum**,
**Chime**, **Click**, **Woodblock**, **Alpha drum**, **Tick**. All are
synthesized live in the browser; nothing is downloaded.

See [Auditory bilateral stimulation](/emdr/auditory-bilateral-stimulation)
for what each sound is and when to reach for it.

Below the preset, two values: the carrier frequency (default 250 Hz,
clamped 200–450 Hz) and the audio volume slider.

## Path

Six motion paths:

* **Horizontal** — classic left-right oscillation (default)
* **Vertical** — top to bottom
* **Diag ↗** — bottom-left to top-right
* **Diag ↘** — top-left to bottom-right
* **Circle** — continuous circular orbit
* **Figure 8** — figure-eight loop

Horizontal is the default for both modes and the most clinically familiar.
The other paths are options for clients who report habituation or visual
fatigue on horizontal.

## Sets

Two steppers — set count and set duration.

* **Set count** — how many sets you plan to run before the session arc card
  closes the session. You can change this mid-session; the card respects the
  current count.
* **Set duration** — clamped to **20 to 40 seconds** in 5-second increments.
  Default is 30 seconds.

The label above reads "**4 × 30s**" — 4 sets, 30 seconds each.

## Photo backdrop

A horizontal row of 16 thumbnails — 8 gradient scenes plus 8 photo
backdrops. Tap to apply.

* **Gradient scenes** (no external fetch) — None, Indigo, Dark, Sunset,
  Forest, Ocean, Void, Warm
* **Photo backdrops** — Forest, Ocean, Mountain, Sky, Lavender, Dawn, Lake,
  Dunes

See [Backgrounds and scenes](/emdr/backgrounds-and-scenes) for which to pick
when.

## Stim size + Audio volume

Two sliders side by side.

* **Stim size** — 16 to 48 px. Default 32 px. The size of the stimulus
  within the frame, which scales to whatever screen your client is on.
* **Audio volume** — 0 to 100%. Default 60%.

## Auto-vary toggle

Off by default. When on, the renderer applies small modulations to speed,
size, and color brightness over the duration of a set — staying within
clinical bounds at all times.

Rationale: monotonous stimulation can let working memory habituate. Mild
parameter variation keeps the dual-task engaging without leaving the
clinical envelope. Engelhard / Littel working-memory taxation research is
the backdrop.

## Dual-task prompts

EMDR 2.0 default is **on**, Classic default is **off**. When on, the
running Workspace surfaces a panel with a dual-task prompt you read aloud
during the set.

See [Dual-task prompts](/emdr/dual-task-prompts) for the prompts, the five
categories, and how to switch between them mid-set.

## SUD check-ins

A **SUD check-ins** control lets you choose how often the Workspace asks
for a SUDS rating: **Every set** (the EMDR 2.0 default) or **Baseline +
end** (the Classic default) — a check before Set 1, an optional check
between sets, and a check at the end. Switching modes resets this to that
mode's default; you can override it either way.

When Baseline + end is selected, the **Start Set 1** button changes to
**Start — baseline first**, so it's clear a SUDS check happens before any
stimulation begins. See [The SUDS scale](/emdr/the-suds-scale) for exactly
how each check-in works, and how optional VOC capture fits in.

## Flash technique (Beta)

Flash is a different technique from standard bilateral stimulation —
select it from the mode toggle and the modal changes shape. Speed, path,
stimulus shape, and audio rows disappear, because Flash doesn't use a
moving stimulus. In their place:

* **Positive engaging focus** — a short text field where you note a calm,
  absorbing memory or image the client holds in mind. This stays on your
  device for the session only — it's never saved to a Rivet server.
* SUD check-ins are locked to **Baseline + end** — Flash captures a
  reading before you begin and one at the close, matching how the
  technique is run in practice.

During the running set, your client sees the positive-focus text on their
screen — calm, steady type, no moving stimulus. When you're ready for a
blink, tap **Flash** on your overlay and a gentle cue plays on their
side: the text pulses softly and a soft chime sounds. That's the signal
for the blink sequence you're guiding verbally. See
[Practitioner controls](/emdr/practitioner-controls) for how the Flash
button behaves during a session.

## Footer — Cancel vs Start Set 1

Two buttons.

* **Cancel** — saves your configuration and closes the modal without
  starting. The next time you tap EMDR, your settings are pre-loaded.
* **Start Set 1** — saves the configuration, closes the modal, and starts
  the first set. The Workspace transitions to the running state. If SUD
  check-ins is set to Baseline + end, this button reads **"Start —
  baseline first"** instead.

If the Workspace is already running and you open the modal mid-session, the
**Start Set 1** button changes to **Apply changes** — the running set
inherits the new configuration the moment the next set begins.

## Related articles

<CardGroup cols={2}>
  <Card title="Visual bilateral stimulation" icon="eye" href="/emdr/visual-bilateral-stimulation">
    Stimulus shapes, paths, sizing, and the 0.3 to 2.0 Hz speed range.
  </Card>

  <Card title="Auditory bilateral stimulation" icon="volume-2" href="/emdr/auditory-bilateral-stimulation">
    Eight synthesized sound presets and the L↔R pan rate.
  </Card>

  <Card title="Photosensitive epilepsy safety" icon="triangle-alert" href="/emdr/photosensitive-epilepsy-safety">
    The 2.0 Hz cap, the first-use warning modal, and what to screen for.
  </Card>
</CardGroup>